39 Mechanical/Bioprosthetic Heart Valves
| Mechanical Valve | Bioprosthetic Valve | Transcatheter Aortic Valve (TAVR) | |
|---|---|---|---|
| Material | Plastic | Bovine, Equine, or Porcine pericardium or aortic valves | Porcine or Bovine pericardium |
| Lifespan | 25-30 years | 10-15 years | 91% of pts at 5-10 yrs have functioning valves |
| Results | Durability ↓ incidence of ppm ↓ risk paravalvular leak |
No AC ↓ incidence of ppm ↓ risk paravalvular leak |
No AC Less invasive procedure ↓ mortality ↓ AKI ↓ bleeding ↓ stroke |
| Drawbacks | AC needed hemolytic anemia invasive procedure |
Shorter lifespan Invasive procedure |
Shorter lifespan |
39.1 Anticoagulation
- Mechanical heart valves that should be on warfarin with an INR goal 2.5-3.5
- mitral valve replacement
- aortic valve replacement w/ risk factors
- 1st 3 months after aortic valve replacement (weak rec)