39  Mechanical/Bioprosthetic Heart Valves

Mechanical Valve Bioprosthetic Valve Transcatheter Aortic Valve (TAVR)
Material Plastic Bovine, Equine, or Porcine pericardium or aortic valves Porcine or Bovine pericardium
Lifespan 25-30 years 10-15 years 91% of pts at 5-10 yrs have functioning valves
Results Durability
↓ incidence of ppm
↓ risk paravalvular leak
No AC
↓ incidence of ppm
↓ risk paravalvular leak
No AC
Less invasive procedure
↓ mortality
↓ AKI
↓ bleeding
↓ stroke
Drawbacks AC needed
hemolytic anemia
invasive procedure
Shorter lifespan
Invasive procedure
Shorter lifespan

39.1 Anticoagulation

  • Mechanical heart valves that should be on warfarin with an INR goal 2.5-3.5
    • mitral valve replacement
    • aortic valve replacement w/ risk factors
    • 1st 3 months after aortic valve replacement (weak rec)